Use this Protection Relay Setting Calculator to calculate pickup current, time multiplier settings (TMS), operating time, coordination time interval (CTI), and plug setting multiplier (PSM)
The document provides calculations for relay settings for different components in a power system network.
The scope of study involves calculating the settings for protective relays to achieve selectivity during faults ocurring in the electrical network for the 13.8 kV and 4.16 kV projects.
There are several approaches for making relay setting calculations. One approach is to calculate a setting and then do a number of checks to verify that the calculated setting is acceptable.
Professional protection relay testing calculator implementing IEEE C37.90 and NETA ATS standards. Calculate pickup values, timing curves, coordination time intervals (CTI), and test injection
Relay coordination is the process of selecting settings that will assure that the relays will operate in a reliable and selective way. In OC relays the coordination is based on the relay time-current
PSM (Plug Setting Multiplier) settings must be in accordance with IEC 60255-151 which specifies performance standards for overcurrent relays and the computation of operational
Calculate thermal overload, overcurrent, ground fault, and differential relay settings with step-by-step examples. Covers CT ratios and common mistakes.
This comprehensive article delves into the key aspects of relay protection in HV/MV substations, including calculations, settings, coordination, selection, and validation, which are all...
These settings may be revaluated during the commissioning, according to actual and/or measured values. Protection selectivity is partly considered in this report, and could be also revaluated.
19-inch racks, wall-mount cabinets, open frames with high load capacity and seismic rating.
IP55/IP66 outdoor enclosures with integrated cooling/heating, -40°C to +55°C operation.
Intelligent PDUs with remote monitoring, per-outlet switching, and environmental sensors.
Prefabricated telecom shelters, emergency comms shelters, and network cabinets with cable management.
We provide custom infrastructure solutions, from telecom racks to smart PDUs and outdoor shelters.
From design to deployment, our team ensures reliable, efficient, and scalable power & enclosure systems.
ul. Głogowska 128, 60-248 Poznań, Greater Poland Voivodeship, Poland
+48 537 928 416 | +48 537 928 416 | [email protected]