BDNW Infrastructure & Power designs and manufactures telecom racks, outdoor climate cabinets, integrated racks, temperature-controlled cabinets, shelters, rack PDUs, smart PDUs, power distribution sys...
Contact online >>
Product features: 1. Eliminates or dampens ferromagnetic resonance caused by voltage transformers, preventing insulation breakdown and discharge inside and outside the voltage transformers; 2. Limits
Available in sizes for use on single and three-phase systems rated 200A or 600A, 15kV through 35kV. Top-hinge design for easy access to all electrical components. All-welded construction.
The MRXH-10 cabinet effectively eliminates resonance and arc grounding overvoltages in power systems, offering a compact and reliable solution compatible with grids up to 35kV.
The device has a fast action speed, which can operate within 30ms~40ms, which can quickly eliminate intermittent arc light and stable arc grounding faults, suppress arc grounding overvoltage, prevent
It includes single-phase ground fault detection, transition fault point location, arc suppression, harmonic suppression, over-voltage alarm, and fault recording functions. Records parameters such as fault
The arc protection system quickly acts to cut off the faulty current, effectively suppressing the occurrence of damage accidents to the main transformer caused by 35kV and 10kV busbar and
It is built as a three-phase encapsulated and arc-resistant solution for both single and double busbar applications, achieving a high classification of Loss of Service Continuity LC2A and partition class PM.
This device can be used for arc suppression, harmonic suppression overvoltage protection, and single-phase grounding line selection in neutral non effectively grounded distribution networks with voltage
Practical operating experience has also proven that in a 3-35KV power grid grounded through an arc suppression coil, accidents caused by arc grounding and resonance occur from time to time.
19-inch racks, wall-mount cabinets, open frames with high load capacity and seismic rating.
IP55/IP66 outdoor enclosures with integrated cooling/heating, -40°C to +55°C operation.
Intelligent PDUs with remote monitoring, per-outlet switching, and environmental sensors.
Prefabricated telecom shelters, emergency comms shelters, and network cabinets with cable management.
We provide custom infrastructure solutions, from telecom racks to smart PDUs and outdoor shelters.
From design to deployment, our team ensures reliable, efficient, and scalable power & enclosure systems.
ul. Głogowska 128, 60-248 Poznań, Greater Poland Voivodeship, Poland
+48 537 928 416 | +48 537 928 416 | +49 174 836 529 | +49 174 836 529 | [email protected]